الخميس، 3 ديسمبر 2009

Indoor Radon Concentration Measurements At Hebron University Campus :A Case Study

An-Najah University Journal for Research - Natural Sciences (A) ISSN: 1727-2114
Volume 10 , 1996, Pages: 092-107

Indoor Radon Concentration Measurements At Hebron University Campus :A Case Study

Fakhri I. Hasan

Associate Professor, Physics Department, Hebron University, Hebron
Received : 00-00-0000 , Accepted : 00-00-0000
Language: English
Abstract

TASTRAK, a solid state nuclear track detector has been used to measure indoor radon concentrations at Hebron University। Fifty- four radon pot detectors were mounted in the four university buildings. It was found that the radon concentrations vary considerably from about 1 Bq/m 3 to 250 Bq/m3 The average radon concentrations vary from 20.5 Bq/m3 in the Main Building to 41.3 Bq/m3 in the Agriculture Building. The average radon concentration in the four buildings is found to be 29.8 Bq/m 3. This leads to an average effective dose equivalent of 1.49 mSvly. This dose is slightly higher than the global value of 1.3 mSv/y. Elevated radon concentrations have been found in few rooms. However, these concentrations are well below the action level of 150 Bq/m3.

http://www.najah.edu/index.php?page=2149&l=en&extra=%26id%3D537

ليست هناك تعليقات:

إرسال تعليق